mirror of
https://github.com/GreemDev/Ryujinx
synced 2024-11-29 13:09:09 +01:00
a33dc2f491
* Logger class changes only Now compile-time checking is possible with the help of Nullable Value types. * Misc formatting * Manual optimizations PrintGuestLog PrintGuestStackTrace Surfaceflinger DequeueBuffer * Reduce SendVibrationXX log level to Debug * Add Notice log level This level is always enabled and used to print system info, etc... Also, rewrite LogColor to switch expression as colors are static * Unify unhandled exception event handlers * Print enabled LogLevels during init * Re-add App Exit disposes in proper order nit: switch case spacing * Revert PrintGuestStackTrace to Info logs due to #1407 PrintGuestStackTrace is now called in some critical error handlers so revert to old behavior as KThread isn't part of Guest. * Batch replace Logger statements
109 lines
No EOL
3 KiB
C#
109 lines
No EOL
3 KiB
C#
using Ryujinx.Common.Logging;
|
|
using System.IO;
|
|
using System.Text;
|
|
|
|
namespace Ryujinx.HLE.HOS.Services.Lm.LogService
|
|
{
|
|
class ILogger : IpcService
|
|
{
|
|
public ILogger() { }
|
|
|
|
[Command(0)]
|
|
// Log(buffer<unknown, 0x21>)
|
|
public ResultCode Log(ServiceCtx context)
|
|
{
|
|
Logger.Guest?.Print(LogClass.ServiceLm, LogImpl(context));
|
|
|
|
return ResultCode.Success;
|
|
}
|
|
|
|
private string LogImpl(ServiceCtx context)
|
|
{
|
|
(long bufPos, long bufSize) = context.Request.GetBufferType0x21();
|
|
|
|
byte[] logBuffer = new byte[bufSize];
|
|
|
|
context.Memory.Read((ulong)bufPos, logBuffer);
|
|
|
|
using MemoryStream ms = new MemoryStream(logBuffer);
|
|
|
|
BinaryReader reader = new BinaryReader(ms);
|
|
|
|
long pid = reader.ReadInt64();
|
|
long threadContext = reader.ReadInt64();
|
|
short flags = reader.ReadInt16();
|
|
byte level = reader.ReadByte();
|
|
byte verbosity = reader.ReadByte();
|
|
int payloadLength = reader.ReadInt32();
|
|
|
|
StringBuilder sb = new StringBuilder();
|
|
|
|
sb.AppendLine($"Guest Log:\n Log level: {(LmLogLevel)level}");
|
|
|
|
while (ms.Position < ms.Length)
|
|
{
|
|
int type = ReadEncodedInt(reader);
|
|
int size = ReadEncodedInt(reader);
|
|
|
|
LmLogField field = (LmLogField)type;
|
|
|
|
string fieldStr = string.Empty;
|
|
|
|
if (field == LmLogField.Start)
|
|
{
|
|
reader.ReadBytes(size);
|
|
|
|
continue;
|
|
}
|
|
else if (field == LmLogField.Stop)
|
|
{
|
|
break;
|
|
}
|
|
else if (field == LmLogField.Line)
|
|
{
|
|
fieldStr = $"{field}: {reader.ReadInt32()}";
|
|
}
|
|
else if (field == LmLogField.DropCount)
|
|
{
|
|
fieldStr = $"{field}: {reader.ReadInt64()}";
|
|
}
|
|
else if (field == LmLogField.Time)
|
|
{
|
|
fieldStr = $"{field}: {reader.ReadInt64()}s";
|
|
}
|
|
else if (field < LmLogField.Count)
|
|
{
|
|
fieldStr = $"{field}: '{Encoding.UTF8.GetString(reader.ReadBytes(size)).TrimEnd()}'";
|
|
}
|
|
else
|
|
{
|
|
fieldStr = $"Field{field}: '{Encoding.UTF8.GetString(reader.ReadBytes(size)).TrimEnd()}'";
|
|
}
|
|
|
|
sb.AppendLine($" {fieldStr}");
|
|
}
|
|
|
|
return sb.ToString();
|
|
}
|
|
|
|
private static int ReadEncodedInt(BinaryReader reader)
|
|
{
|
|
int result = 0;
|
|
int position = 0;
|
|
|
|
byte encoded;
|
|
|
|
do
|
|
{
|
|
encoded = reader.ReadByte();
|
|
|
|
result += (encoded & 0x7F) << (7 * position);
|
|
|
|
position++;
|
|
|
|
} while ((encoded & 0x80) != 0);
|
|
|
|
return result;
|
|
}
|
|
}
|
|
} |