powerpc: Reset MSR_LE on signal entry

We always take signals in big endian which is wrong. Signals
should be taken in native endian.

Signed-off-by: Anton Blanchard <anton@samba.org>
Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
This commit is contained in:
Anton Blanchard 2013-09-23 12:04:43 +10:00 committed by Benjamin Herrenschmidt
parent ef1967ff87
commit e871c6bbf6
2 changed files with 4 additions and 2 deletions

View file

@ -1045,8 +1045,9 @@ int handle_rt_signal32(unsigned long sig, struct k_sigaction *ka,
regs->gpr[5] = (unsigned long) &rt_sf->uc;
regs->gpr[6] = (unsigned long) rt_sf;
regs->nip = (unsigned long) ka->sa.sa_handler;
/* enter the signal handler in big-endian mode */
/* enter the signal handler in native-endian mode */
regs->msr &= ~MSR_LE;
regs->msr |= (MSR_KERNEL & MSR_LE);
#ifdef CONFIG_PPC_TRANSACTIONAL_MEM
/* Remove TM bits from thread's MSR. The MSR in the sigcontext
* just indicates to userland that we were doing a transaction, but we

View file

@ -773,8 +773,9 @@ int handle_rt_signal64(int signr, struct k_sigaction *ka, siginfo_t *info,
/* Set up "regs" so we "return" to the signal handler. */
err |= get_user(regs->nip, &funct_desc_ptr->entry);
/* enter the signal handler in big-endian mode */
/* enter the signal handler in native-endian mode */
regs->msr &= ~MSR_LE;
regs->msr |= (MSR_KERNEL & MSR_LE);
regs->gpr[1] = newsp;
err |= get_user(regs->gpr[2], &funct_desc_ptr->toc);
regs->gpr[3] = signr;