regulator: wm8400: Use DIV_ROUND_UP macro to calculate selector

Use DIV_ROUND_UP macro for better readability.

Signed-off-by: Axel Lin <axel.lin@gmail.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
Axel Lin 2012-03-06 09:56:05 +08:00 committed by Mark Brown
parent 1c37f8a838
commit e9a15c8cad

View file

@ -78,14 +78,14 @@ static int wm8400_ldo_set_voltage(struct regulator_dev *dev,
if (min_uV < 1700000) {
/* Steps of 50mV from 900mV; */
val = (min_uV - 850001) / 50000;
val = DIV_ROUND_UP(min_uV - 900000, 50000);
if ((val * 50000) + 900000 > max_uV)
return -EINVAL;
BUG_ON((val * 50000) + 900000 < min_uV);
} else {
/* Steps of 100mV from 1700mV */
val = ((min_uV - 1600001) / 100000);
val = DIV_ROUND_UP(min_uV - 1700000, 100000);
if ((val * 100000) + 1700000 > max_uV)
return -EINVAL;
@ -168,7 +168,7 @@ static int wm8400_dcdc_set_voltage(struct regulator_dev *dev,
if (min_uV < 850000)
return -EINVAL;
val = (min_uV - 825001) / 25000;
val = DIV_ROUND_UP(min_uV - 850000, 25000);
if (850000 + (25000 * val) > max_uV)
return -EINVAL;