* ARM Vectored Interrupt Controller
|
|
|
|
One or more Vectored Interrupt Controllers (VIC's) can be connected in an ARM
|
|
system for interrupt routing. For multiple controllers they can either be
|
|
nested or have the outputs wire-OR'd together.
|
|
|
|
Required properties:
|
|
|
|
- compatible : should be one of
|
|
"arm,pl190-vic"
|
|
"arm,pl192-vic"
|
|
- interrupt-controller : Identifies the node as an interrupt controller
|
|
- #interrupt-cells : The number of cells to define the interrupts. Must be 1 as
|
|
the VIC has no configuration options for interrupt sources. The cell is a u32
|
|
and defines the interrupt number.
|
|
- reg : The register bank for the VIC.
|
|
|
|
Optional properties:
|
|
|
|
- interrupts : Interrupt source for parent controllers if the VIC is nested.
|
|
- valid-mask : A one cell big bit mask of valid interrupt sources. Each bit
|
|
represents single interrupt source, starting from source 0 at LSb and ending
|
|
at source 31 at MSb. A bit that is set means that the source is wired and
|
|
clear means otherwise. If unspecified, defaults to all valid.
|
|
- valid-wakeup-mask : A one cell big bit mask of interrupt sources that can be
|
|
configured as wake up source for the system. Order of bits is the same as for
|
|
valid-mask property. A set bit means that this interrupt source can be
|
|
configured as a wake up source for the system. If unspecied, defaults to all
|
|
interrupt sources configurable as wake up sources.
|
|
|
|
Example:
|
|
|
|
vic0: interrupt-controller@60000 {
|
|
compatible = "arm,pl192-vic";
|
|
interrupt-controller;
|
|
#interrupt-cells = <1>;
|
|
reg = <0x60000 0x1000>;
|
|
|
|
valid-mask = <0xffffff7f>;
|
|
valid-wakeup-mask = <0x0000ff7f>;
|
|
};
|